UM-2A Portable UV Sterilizing Lamp

 
 

Usage And Maintenance Parameters of UM-2A Portable UV Sterilizing Lamp

Power supply voltage

220V 50HZ

Ultraviolet lamp tube power

30W

Ultraviolet radiation wavelength

253.7NM

Ultraviolet radiation

>100 uw/CM2

Automatic control of disinfection time

0-120 minutes

 

 

Usage of UM-2A Portable UV Sterilizing Lamp

1. Open the protective door, take out the lamp arm, and slowly lift it to the required height, generally at an Angle of 90 degrees from the ground.

2. Turn on the timer clockwise and set the disinfection time for 30-45 minutes.

3, plug in the power, open the switch, sterilization work, personnel leave the scene, set up a disinfection label.

4. After disinfection, turn off the starting switch, unplug the plug, hold the lamp arm by hand, press the lamp wall adjustment button, lower the lamp arm and close the protective door.

 

 

 

Disinfect Area And Time

 

power

Disinfection area

time

30minutes

 

60minutes

90minutes

120minutes

 

Single 30w tube

 

30 ㎡

 

35 ㎡

 

35 ㎡

 

35 ㎡

 

Double 30w tube

 

50 ㎡

 

65 ㎡

 

65 ㎡

 

70 ㎡

 

 

 